產品性能及優勢 性能 用于在腹腔鏡下手術中收攏組織、經皮縫合,以便閉合手術切口。 優勢 · 性能可靠 · 適用各類體型患者,達到1厘米的筋膜收攏效果 · “由內而外”,獨特閉合 · 有效控制進針深度,安全性能高 · 最大限度地降低針刺傷害 近端活動翼板 · 鎖定后,能保持穩定 · 解鎖后,能張合自如 · 提示腹壁位置 · 便于控制進針 · 固定縫合線兩端 · 固定穿刺孔兩側1厘米處的縫合邊距 導引通道 · 最大限度地減少針刺傷害風險 · 縫線穿引器向控制板遞送縫線的路徑 縫線穿引器 獨特的U形角度設計,配合高精密生產設備,保證U形孔槽弧度的同時最大程度降低表面粗糙度。 材料 采用進口優質原材料,保證縫線穿引器擁有超強的硬度、剛性、韌性、耐腐蝕性及刺穿力。
Performances and advantages Performance It can be used to close tissues and suture through skin in endoscopic surgeory in order to close surgical incision. Advantages · Reliable · Applicable for patients with variety of body shapes, up to 1 cm of fascia closure. · "From inside to outside", a special suture pattern · Effective control of needle depth with improved safety performance · Reducing needle damage to maximum degree Near-end movable wings · When locked, it can be stable · Unlocked, it can freely open and close · Indicate position on the abdominal wall · Easy to control needle depth · Fix both ends of suture · Fix edges at 1 cm from both sides of the trocar incision Leading passage · Reducing needle damage hazard to maximum degree · The path from the suture leading device to the control panel Leading device for suture A special U-shape design with high precision manufacturing facilities to guarantee the curvature on the slot while keep the surface roughness to the lowest degree. Material It applies imported high quality raw material to assure outstanding hardness, rigidity, flexibility, corrosion resistance and penetration force of the leading device.
產品信息 product information 
產品使用方法 1、開啟包裝,取出閉合固件和縫線穿引器,將閉合固件插入穿刺孔內,隨后將手環順時針旋轉至解鎖后向上提拉手環,此時兩側近端活動翼板在穿刺孔內的皮層筋膜下方處于打開狀態;再將手環逆時針旋轉至鎖定,使得兩側近端活動翼板處于張開鎖定狀態。 2、將備用縫合線從一端約50mm處掛入縫線穿引器的穿引針前端的U形孔槽內,腹部向上輕提,將掛有縫合線的縫線穿引器沿閉合固件一側的導引孔插入體內,穿引針穿透穿刺孔一側的皮膚組織,同時插穿近端活動翼板上的窗口膜片。 3、緩慢抽出縫線穿引器,縫合線的線頭在窗口膜片的夾持作用下留在體內;重復上述過程操作,完成穿刺孔(切口)兩側縫合線插入。 4、將手環順時針旋轉至解鎖后按下手環,使得兩個近端活動翼板再次處于閉合狀態,并夾持住從兩側插入的縫合線;再將手環逆時針旋轉至鎖定,從穿刺孔(切口)緩慢抽出閉合固件,同時把縫合線帶出體外,將縫線兩端從控制面板中抽出,用標準技術結扎縫線,完成縫合。 Methods
1.Open the package, take out the fixture and suture leading device, then insert the fixture into the incision. Then turn the finger ring clockwise to the unlock position and pull up. Now the near- end movable wings are open under fascia inside the incision. Then turn the ring counterclockwise to lock position to keep the movable wings open and locked. 2.Hang the backup suture at 50mm from one end onto the U- type slot at the front of the leading needle and pull up slightly, then insert the leading device with suture into hum an body alongside the closure fixture. The needle will penetrate both the skin at the trocar side and the window m embrane on the movable wings. 3.Pull out the leading device slowly and the ends of the suture will stay inside human body under the gripping pre ssure of the membrane. Repeat the above process until both sutures are inserted around the incision. 4.Turn the finger ring clockwise to the unlock position and push down to keep both movable wings closed again and both sutures gripped. Then turn the ring counterclockwise to lock position, slowly pull out the fixture through the incision together with the suture. Pull out both ends of the suture from the control panel. Finish the suture process with standard technique. 
|